Please wait...

42" 279.2 ft² Shell & Tube Exchanger

Listing ID:
IH-46808

General Info
Year Built:
2009
Service Type:
Sour
PASC Condition Rating:
A
Skidded:
No
Housed:
No
Connection Status:
Disconnected
Warranty:
No
Units Available:
1
Exchanger Info
Exchanger Type:
Shell & Tube
Manufacturer:
Enerflex Production & Processing
Model #:
N/A
Diameter:
42"
Length:
30'
Shell Pressure:
190 PSI
Tube Pressure:
2200 PSI
Max Temp:
400°F
Heat Surface Area:
279.2 ft²
Serial #:
B7562-21
CRN #:
U9169.21
Notes:
  • HEAT EXCHANGER SHELL & PIPE (3″)
  • Manufacturer: Enerflex in 2009
  • Pipe Surface Area: 279.20 Ft.²
  • Size: 42″ OD x 30′-0″ S/S
  • Shell: 190 PSI @ 400° F
  • Pipe: 2200 PSI @ 400° F Sour Service
  • Pipes (3″ OD): 8 Passes of 3″ Sch. 160, 28′ L
  • Head Material: SA-516-70N
  • Shell Material: SA-516-70N
  • Pipe Material: SA-333-Gr. 6
  • Corrosion Allowance: 0.125″
  • P.W.H.T: Yes
  • Radiography: 100% (RT-1)
  • “U” Stamp: Yes
  • Insulated: No
  • Shell Inlet: 4″ 300# RFWN
  • Shell Outlet: 4″ 300# RFWN
  • Pipe Inlet: 4″ 1500# RFWN
  • Pipe Outlet: 4″ 1500# RFWN
  • Weight: 18,600 LBS
Financial Info
Availability Status
Available
Location
Nearest Town / City
Beiseker
Province
AB
Country
Canada
Share item via

Indirect Fired Heaters