Please wait...

2,803 BPD Debutanizer Package (NEW - Never Used)

Listing ID:
IH-46673
Published

Item Info
Misc Type:
Process Equipment
Misc Item Title:
2,803 BPD Debutanizer Package (NEW - Never Used)
Year Built:
2015
Manufacturer:
Propak Systems Ltd
Serial #:
143431-111-02
Pressure:
200 PSI
CRN #:
W-7926.23
General Info
Service Type:
Sweet
PASC Condition Rating:
A
Condition Details:
Never put in service
Skidded:
Yes
Housed:
Yes
Connection Status:
Disconnected
Building / Skid Info
Building Length:
40ft
Building Width:
20ft
Building Height:
22ft
Notes:

This de-butanizer package is required to produce high value condensate. The package will separate and send any incoming gas off to the compressors, preheat the inlet stream with the tower bottoms high value condensate, and reflux the gas off the top of the tower through a condenser. Gas from the tower will go to the inlet separator and condensate will be cooled and sent to storage.

 

De-Butanizer Design Conditions

Quantity

One (1)

Service

Sweet

Design Class*

150 ANSI 200 psig @ 204oF

1,379 kPag @ 96°C

Liquid Inlet Rate (Wild Condensate)

2,803 BPD

446 m3/d

Stabilized Condensate Production

2,315 BPD

368 m3/d

Condensate Temperature to Storage

104oF

40°C

Cooler Ambient Design Temp.

90oF

32°C

*Flanges to be 300#

 

The package will include the following equipment:

  • V-140 feed flash drum (4’ ID x 10’ S/S or 1219 mm x 3048mm)

o Turbine meter on FFD water boot outlet

  • Two (2) @ 100% feed pumps (10HP SPX VLK-BB)
  • Three (3) BEU feed/bottoms heat exchangers (1’-4” OD x 15’ FOF/S or 406 mm OD x 4572 mm FOF/S // Shell & Tube sides rated: 200 psi @ 96oF or 1379 kPag @ 204oC)
  • V-500 debutanizer tower with break flange at roof and platform for access (3’ ID x 62’ S/S or 914 mm ID x 18898 mm S/S)
  • Reflux system consisting of:

o Cooler (Air-X 15HP)

    • drum (V-573 3’-6” ID x 10’ S/S or 1067 mm ID x 3048 S/S), and
    • two (2) @ 100% Sundyne pumps (5HP) – to be confirmed
  • H-633 Reboiler (details to follow)
  • Rundown cooler (Air-X 25 HP VFD compatible)
    • Fuel gas scrubber
  • Micromotion meter to measure condensate before storage
  • BDV sized to relieve to 60 psi in 15 minutes
  • Gate valves will be used on all hot service piping

 

The coolers and reboiler will be installed separately; all other equipment will be packaged on a vendor-supplied skid with a building.

Financial Info
Availability Status
Available
Location
Nearest Town / City
Drayton Valley
Province
AB
Share item via

Indirect Fired Heaters


There is no category.