11840 kW Solar Turbine Titan 130 with SoLoNOx Gas Turbine Generator Package
(1) complete unit combined with steam turbine
11,840 MW Gas turbine / 7 MW steam turbine
18,840 total MW plant
Gas fired
Waste Heat Recovery Boiler
Turbine engine:
Manufacturer: Solar Turbines INC, San Diego USA Model: Titan 130 with SoLoNOx combustion,
Packager: Turbomach
Year of Manufacture: 2005
Operating hours: about 15.500 (whole plant), 150 starts
Was operated until 2007, after that standby
Condition: fully serviced by Turbomach and ready for start.
Capacity: 11.840 kW
Speed: 11.215 RPM continual
Fuel: Natural Gas with input pressure of 28 bar
Fuel /gas consumption: around 3.700 Nm³/h (calorific value 10.4 kWh/m³)
Burners: 14
Start system: electro. Hydraulic, 110 kW
Outlet temperature: 486°C Exhaust gas volume: 131.000m³/h
Dimensions: longitudinal-and transverse-force bases
Turbine: 9m x 2,2m x 2,8m = 33 tons
Strainer: 4m x 2,9m x 3,8m = 4.8 tons Insulating dome: 9m x 2,2m x 3,25m = 7 tons
Mounting: On steel skid (with acoustic enclosure)
Reduction Gearbox
type: Solar Epicyclic Reduction Gearbox
Output rpm: 1500
Year Manufactured: 2005
Generator
Manufacturer: Leroy Somer
Type / Model: LSA 58 BMCL 14-4P.
Frequency: 50 Hz
Voltage: 5.25 kV
Power: 14.800 kVA, PF = 0.8
Speed: 1500
Year manufactured: 2005
Speed 1.500 RPM max. 1.800 RPM
Power: 9.000 kVA
Fire protection system
Control systems turbine
Turbomach TTS3
Auxiliaries
Lubrication System Fuel System
Start System electro-hydraulic 110 kW Air inlet system, 1 stage air filter system Exhaust system complete with silencer
Waste Heat Recovery Boiler
Manufacturer: IEG, Livice (Slovakia)
Type: Natural circulation boiler with additional firing 2 modules of finned tubes
Steam with add. Burner: 44.5 t/h, max. 47 t/h - 58 bar, 510°C, O2 14.8% Steam without add. Burner 18.5 t/h - 58 bar, 440°C, O2 15.7% Burner: 3 burners with 730 Nm³ each at full load
Fuel: Natural Gas H
Cal. Value: 10.4 kWh/m³
Gas pressure input: 3.5 Bara
Chimney
Type two-layered, inside stainless steel
Dimension: 40 m high, exhaust 3.8 m²
Exhaust temp. 220°C (limited with compensator)
Feed water system
Pumps: 30 t/h, 75 bar,
3 x 50%, one in reserve
Steam turbine
Type: B+V, MARC2 – B10, back pressure with extraction Live steam pressure 58 bar 60.5 bar max
Live steam temp.: 510°C
Steam quantity: 45 t/h
Extraction pressure: 21 bar 24.0 bar max Extraction temp.: 383°C 490°C max Extraction quantity: 7 t/h 15 t/h max Exhaust pressure: 3 bar 4 bar max Exhaust temp. : 180°C 262°C max Exhaust quantity: 28 t/h 47 t/h max Speed: 10.043 RPM
Quick closing speed: 11.047 RPM
Plant is in excellent condition,
Maintained and serviced by Turbomach on regular basis, boiler and steam turbine dry and hot conserved. Ready for immediate start of dismantling