60" 1445psi Sour Horizontal 3-Phase Horizontal Separator 3 Phase
bookmark_border WatchSupporting Documents (2)
library_books60" ID x 20' horizontal 3-phase separator by Hanover Maloney (2002, CRN P5114.21, A-483121), 1445 psig MAWP @ 125°F, MDMT -40°F, PWHT, 10" 600# inlet/gas outlet. Skidded with attached heated control building. Disconnected, Stettler, AB.
60" ID x 20'-0" Horizontal 3-Phase Separator – 1445 psig, Hanover Maloney, 2002, Skidded & Housed
VESSEL (per ASME U-1A data report and nameplate)
- Manufacturer: Hanover Maloney Inc. (Calgary, AB); ASME Section VIII, Div. 1 (1998 edition, A00 addenda), U-stamped, Code Case 2235-3 (UT of long and circ seams)
- Serial No. 01-C5404-3000; National Board No. 119; CRN P5114.21; Alberta A-number A-483121; year built 2002
- Size: 60" ID x 20'-0" overall, horizontal; volume 436 ft³ (12.34 m³)
- MAWP: 1445 psig @ 125°F; MDMT: -40°F @ 1445 psig; hydrostatic test: 1880 psig
- Shell: SA-516-70N, 2.50" nominal; heads: SA-516-70N 2:1 ellipsoidal, 2.40" min.; corrosion allowance 0.125"
- PWHT: 1150°F for 2-1/4 hr; impact tested (LCVN test head, shell plates and production weld to 15/12 ft-lb @ -40°F); nameplate marked RT: FULL
- Nozzles SA-350-LF2, 600# RFWN unless noted; supports: welded saddles
NOZZLES (per U-1A)
- Inlet / gas out: 2 x 10" 600# RFWN
- Water / oil out: 2 x 3" 600# RFWN
- Drains: 3 x 2" 600# RFWN
- Relief valve: 2 x 4" 600# RFWN
- Oil level control: 2 x 2"; water level control: 2 x 2"; oil LSH/LSL/LG: 2 x 2"; water LSL/LG: 2 x 2" (all 600# RFWN)
- Pressure indicator 1/2" TOL; temperature 3/4" TOL; blowdown 1" TOL (6000#)
- Handhole: 6" 600# RFHB; manway: 18" 600# RFHB
PACKAGE (per last-service P&ID and photos)
- Skid-mounted vessel with attached control building housing the level controls, liquid control valves, instrumentation and ESD station; exterior of the vessel insulated with aluminum cladding
- Last-service P&ID shows level controllers and switches on oil and water legs, gas back-pressure control, PSV (set at 175 psig in last service), gas meter, catalytic building heaters (12,000 BTU/hr, 120 VAC), exhaust fan and a 20 HP progressive-cavity booster pump within the building limit
- Last-service P&ID notes call for removal of the weir for 2-phase operation; buyers requiring 3-phase service should confirm the weir/internal configuration at inspection
CONDITION & STATUS
- Used, good condition (PASC B); disconnected; located near Stettler, AB
- Offered for sour service; NACE MR0175 documentation is not in the public file – request from the seller if required
- Documents available: ASME U-1A data report (ABSA), last-service P&ID; 28 photos including nameplate and building interior
BUYER NOTES
- Registered vessel (CRN P5114.21 / A-483121); confirm current ABSA registration and inspection status before re-installation.
- PSV and instrumentation are as last installed; re-certify relief devices for the new service pressure.