48"x8' Universal Industries Sweetening Skid w/ 200 bbl DW Tank
Supporting Documents (3)
library_booksH2S Removal Contactor:
-48”OD x 8’– 0” S/S MWP 1440 PSIG Sweetening tower
- Ultrafab engineered design
- Design data: 2001 ASME code section VIII Div 1 VW – 12A Registered BC, AB, SK
- Service: Sour
- Radiography – Full
- Corrosion Allowance – 1/8”
- PWHT – Yes
- Proprietary internal design for improved contact
- Internal down comer for freezing prevention
Separator
36” x 7’ – 6” S/S MWP 1440 PSIG 3 Phase Separator Description:
Registered in AB,BC, SK
- Service Sweet, Radiography: full long seams, spot circ. Seams
- Corrosion allowance 1.8 mm, PWHT - No
- 1 Norriseal Level controllers
- 1 Norriseal Dump Valve and 1” Piping
- 1 Level Gauge Queststar
- 3”x3” “K” PSV on Vessel (sweet)
- Anti-corrosion drain design
Pumps
- 4 – Milroyal C Chemical Injector Pumps c/w PSV, rated at approx.10,000 l/d ea.
- Bellofram regulators used throughout
- Vent regulators and diaphragms outside of building
Heater
- One (1) 2 KVa Roughneck Electric 460 Volt 3 PH